SEL-111K Chiffon is an active information protection from TEMPEST (Telecommunications Electronics Material Protected from Emanating Spurious Transmissions) leakage channel.
The system is designed to prevent unintentional emanation of classified information from a computer equipment by generating an electromagnetic field noise interference signal over a wide frequency range in space and electrical noise signals on the conductors, including on the ground circuit and the power supply conductive lines and engineering communications beyond the controlled area.
Capabilities and features of the system:
• Use of the thermal noise source with digital processing provides a uniform linear spectrum of the noise signal over the entire frequency range.
• Separate adjustment of the output level of the noise per band allows optimal way to form a "protective interference" by reducing the levels of spurious electromagnetic radiation.
• Digital autonomous (password protected) management and control of system settings with the information output to the built-in LCD screen.
• Remote control over Ethernet allows combining devices in a network to form a distributed information protection system of any object.
• The built-in counter of the total operating time of the generator interference with the registration of values in a secure non-volatile memory.
• Distributed control system and indicating normal operation or an emergency in parts of the system (visual, audio, text).
• Use a flat UWB antenna PA-111 significantly reduces installation time and system settings.
The composition and construction of the system:
Structurally the system consists of a dual-channel noise generator loaded on antennas for spatial noising, pointing device noise signal on the conductive lines and communications, as well as control devices and monitoring the health of the system. Power supply and guidance device may be either embedded in the block noise generation, and separately connected by wire.
The basic system configuration:
• Central noise generation block SEL-111G;
• Telescopic (whip) antenna TA-111
• signal directing device to the power lines NS-111.
Additional elements of the system:
• Ultra-wideband flat antenna PA-111;
• Wired remote control SEL SP-810 ;
• Wired via Ethernet controller bundled with specialized software SEL SP-830.
The amount and composition of the elements of the system is selected depending on the characteristics and category of protected object.
Specifications
The system is designed to prevent unintentional emanation of classified information from a computer equipment by generating an electromagnetic field noise interference signal over a wide frequency range in space and electrical noise signals on the conductors, including on the ground circuit and the power supply conductive lines and engineering communications beyond the controlled area.
Capabilities and features of the system:
• Use of the thermal noise source with digital processing provides a uniform linear spectrum of the noise signal over the entire frequency range.
• Separate adjustment of the output level of the noise per band allows optimal way to form a "protective interference" by reducing the levels of spurious electromagnetic radiation.
• Digital autonomous (password protected) management and control of system settings with the information output to the built-in LCD screen.
• Remote control over Ethernet allows combining devices in a network to form a distributed information protection system of any object.
• The built-in counter of the total operating time of the generator interference with the registration of values in a secure non-volatile memory.
• Distributed control system and indicating normal operation or an emergency in parts of the system (visual, audio, text).
• Use a flat UWB antenna PA-111 significantly reduces installation time and system settings.
The composition and construction of the system:
Structurally the system consists of a dual-channel noise generator loaded on antennas for spatial noising, pointing device noise signal on the conductive lines and communications, as well as control devices and monitoring the health of the system. Power supply and guidance device may be either embedded in the block noise generation, and separately connected by wire.
The basic system configuration:
• Central noise generation block SEL-111G;
• Telescopic (whip) antenna TA-111
• signal directing device to the power lines NS-111.
Additional elements of the system:
• Ultra-wideband flat antenna PA-111;
• Wired remote control SEL SP-810 ;
• Wired via Ethernet controller bundled with specialized software SEL SP-830.
The amount and composition of the elements of the system is selected depending on the characteristics and category of protected object.
Characteristics: | |
The range of the generated noise signal | 10 kHz – 1.0 GHz |
Entropy noise ratio | 0.9 |
Output of the magnetic antenna terminal | 0.01 - 30 MHz |
Output RF antenna, SMA connector | 0.01 - 3000 MHz |
The output terminals for connecting to wires, plug | 0.01 - 400 MHz |
Range of noise level adjustement | from 0 to -30 dB |
Sub-band intervals to adjust the noise level at the output "A" | 0.01-30, 30-140, 140-260, 260-400, 400-700, 700-1000 MHz |
Sub-band intervals to adjust the noise level at the output of the "B" | 0.01-1, 1-30, 30-140, 140-400 MHz |
Built-in LCD screen size | 62x18 mm |
Indication of normal operation | LED and text |
Indication of emergency mode | LED, text and audible (buzzer) |
Controlling options | using panel, using remote control or network, Ethernet 10/100 |
Power supply | 220 V 50 Hz or via an external DC adapter 12V 2A |
Dimensions of generator | 225x150x75 mm |
The device confirms with the essential safety requirements of the following EU New Approach Directives as ammended:
2014/35/EU Low Voltage Directive
2014/30/EU Electromagnetic compatibility
2014/30/EU Electromagnetic compatibility