Countersurveillance technologies
+7 (495) 223-62-22

ST 300 SPIDER line and mains analyser

DESCRIPTION
Line and mains analyzer ST-300 “Spider” is designed to detect and locate eavesdropping devices, galvanically connected to power and low-current wire lines in the inspected object. The analyzer uses both passive and active modes of operations. This allows detecting eavesdropping devices which are in active or in stand-by mode at the time of a sweep operation.

In ST-300 “Spider” there are set of functions implemented, which are most necessary for the detection and localization of wired eavesdropping devices. These functions include:
• Detection and evaluation of low-frequency signals in low-current conductive lines;
• Activation of electret cable microphones by filing an in-line bias voltage;
• Detection of eavesdropping devices signals, which are transmitting information via power and low-current lines in the frequency range from 100 kHz to 150 MHz;
• Detection and assessment of unauthorized galvanic connections to conductive lines using methods of non-linear junction detection and reflectometry;
• Tracking wire lines laid in walls and other building structures using trace locator.

Use of automated mode of analyzer, in combination with electronic switch, allows to carry out various kinds of measurements on all the possible combinations of pairs of multi-wire cable in a few seconds. Adapters, couplers and cables, which are included in the set of ST-300 SPIDER delivery set, allow to connect the device to the most common types of wired lines. The device can be used in standalone mode or controlled from a personal computer.

The solution of different ways to detect wired eavesdropping devices is ensured by the multifunctionality of ST-300, appropriate accessory pack and the use of passive and active modes of operation. Systems technical and programming basis, implemented in the structure and unique algorithms allows to use it in the following modes:
• Electronic switch;
• Low frequency amplifier;
• Wireline receiver;
• Nonlinear junction detector for wire lines;
• Reflectometer;
• Trace locator.
Specifications
Characteristics:
Low frequency Amplifier
Frequency range 20....25 000 Hz
Input impedance 200 Ohm
Amplification regulation range 0....60 dB
Maximum signal amplitude on the entrance ± 13.8 V
Bias voltage range ± 26 V
Wireline receiver
Frequency range 100....150 000 kHz
Time to scan the entire range 2 s
The minimum detectable signal level -50....-75 dBm
Dynamic range 55 dB
Input impedance 50 Ohm
Demodulation AM, FM
The filter bandwidth 80 kHz
The maximum allowable voltage In 250 (AC), 80 (D?)
Non linear junction detector
Signal Amplitude 0....13 V
Signal frequency 45....55 Hz
Minimally detected level of non linear distortions -60 dB
Power Supply and Dimensions
Time of continuous operation from built-in Li-pol accumulator not less than 7 h
Dimensions of the main unit (length, width, height) 175?83?36 mm
Weight of the main unit 0.375 kg
Package dimensions (length, width, height) 390?310?170 mm
Weight of the set in the package 4.4 kg Reflectometer
Diapason of distance
0...100 m Digital Voltmeter
Measurement range
DC ± 80 V The measurement range AC 13 V Trace locator
Carrier frequency of the test signal
100 kHz